A metal detector is a critical control point when it's the last step that can catch metal before the food is sealed and shipped. Its critical limit isn't "no metal", which nobody can monitor. It's this: the detector is on, every pack goes through it, and it rejects each of its test pieces every time it's checked. The test pieces are the smallest ferrous, non-ferrous and stainless steel spheres the machine reliably finds in your product, worked out when it's set up. FDA treats a hard or sharp object 7 to 25 mm long in ready-to-eat food as adulteration, and smaller ones where infants or the elderly are among the consumers, so test pieces sit far below that line. Below are the limit, the checks, what to do when one fails, and a worksheet.

The short version

  • The limit: detector on, and all three test pieces rejected at every check.
  • Test pieces: ferrous, non-ferrous and stainless steel, sized for your product and aperture.
  • Check at start-up, at a set interval, at each product change, after repairs, and at the end.
  • A failed check puts everything since the last good check on hold.
  • Open and look at every reject.
  • TaroStack keeps each check with its batch, and the lot on hold. More below.

Is it a CCP?

Where metal comes from Example What should catch it first
Ingredients Wire, staples, shot, harvester parts Supplier specification, sieve, magnet
Equipment Blade chips, mixer bolts, sieve wire, can-opener shavings Blade and sieve checks, maintenance
People and repairs Tools, drill swarf, a nut left behind Clean-up and sign-off after every repair
Packaging Carton staples, foil No staples in the room

The detector is a CCP if your hazard analysis finds metal reasonably likely and the detector is the control you rely on to catch it. Under FDA's preventive controls rule it's a process control like any other, with a limit, monitoring, corrective action, verification and records. It doesn't replace the first-line controls in the table. A detector finds a blade tip. It doesn't find the reason the blade broke. The written program for all of them is in foreign material control program.

The limit, and the test pieces

A made-up line packing bagged granola. Its sizes are its own.

Critical limit Detector on; every pack passes through; each test piece rejected into the locked bin at every check
Test pieces 2.0 mm ferrous, 2.5 mm non-ferrous, 3.0 mm stainless steel
How Each piece sent through inside a pack of product: at the leading end, the middle and the trailing end
When Start of the run, every hour, each product change, after any stop or repair, the end of the run

Why three metals. Detectors find iron most easily and stainless steel least, and most food equipment is stainless.

Why sizes differ by product. Wet, salty or warm food (fresh bread, cheese, meat) gives a signal of its own, called product effect, and the detector has to be set less sensitive to ignore it. A larger aperture is less sensitive too. So nobody can give you sizes from a table. Whoever sets up the machine establishes what it reliably detects in your product, and those become your test pieces. Customers and audit standards often set maximum sizes as well: check theirs.

Why inside a pack. A test piece waved through an empty aperture proves little. It should travel as the product does, and be rejected as a pack is.

FDA's own line is much larger than any test piece. CPG Sec. 555.425 treats hard or sharp objects 7 mm to 25 mm long in ready-to-eat food as adulteration, and smaller ones when the food is for infants, the elderly or others at special risk. A detector that finds 2 to 3 mm spheres is working well inside it.

When a check fails

  1. Stop the line.
  2. Put everything packed since the last good check on hold. This is why the interval matters: hourly checks mean an hour of product at most.
  3. Find the cause: the wrong product setting, sensitivity changed, or a reject device that didn't fire.
  4. Fix it, and pass all three test pieces again.
  5. Send the held product back through the working detector.
  6. Write down what failed, what was held, and what happened to it.

Rejects. Every rejected pack goes into a locked bin, and someone opens each one. Real metal is a finding: what is it, where did it come from, and is the rest of the batch safe? A false reject is information too. Packs put back on the line unexamined are how a working detector fails.

Verification. Have the detector serviced and calibrated on a schedule, keep the certificate, and have a second person review the check records. Under FDA's rule, monitoring and corrective action records are reviewed within 7 working days.

A morning of checks

Time Check Ferrous 2.0 mm Non-ferrous 2.5 mm Stainless 3.0 mm OK?
7:00 Start of run Rejected Rejected Rejected Yes
8:00 Hourly Rejected Rejected Rejected Yes
9:00 Hourly Rejected Rejected Not rejected NO: act
9:25 After repair Rejected Rejected Rejected Yes
10:00 Product change Rejected Rejected Rejected Yes

At 9:00 the stainless piece went through. The reject flap's air line had worked loose: the detector saw the piece and nothing pushed the pack off. The 412 packs made since 8:00 were held, the line was fixed, and all 412 went back through at 9:40. None was rejected.

This is general information, not legal advice. The log on its own is in metal detector log, glass and hard plastic in glass and brittle plastic policy, and how a limit is written in critical limits for CCPs.

Get the worksheet

Download the metal detector CCP worksheet. Three sheets and a read-me: the hazard analysis for metal from receiving to packing, the plan for the detector as a control point, and a monitoring log. It's an ordinary Excel file with no macros, and it works in Google Sheets, LibreOffice and Numbers.

Where this stops working

The 9:00 check failed. Which packs were made between 8:00 and 9:00? If the answer is "the ones on that pallet, probably", and half of that pallet left on the 8:30 truck, the hold has become a recall. A paper log records that a check failed. It doesn't say where an hour of product went.

How TaroStack does it

TaroStack keeps the checks with the batch they belong to.

Each run is a batch with a lot code. Your checks are fields on its record: test pieces rejected, time, initials.

Put the lot on hold when a check fails, and it's kept out of what you can sell until someone releases it.

If some has shipped, one report lists which customers got that lot and how much. Starting a recall holds what's left.

Lot labels print with the code, so the pallet says which batch it is.

The failed check Paper log In TaroStack
Which packs since the last good check That pallet, probably The batch's lot
Keeping them off the truck A sign on the pallet On hold
What already shipped Bills of lading One report
Proof the check was done A clipboard On the batch record

TaroStack doesn't run the detector or set its sensitivity. Recipes, batches, lots and recalls are on every plan, from $9.99 a month (5 recipes) or $39 a month (50 recipes, with allergen tracking). The first 14 days are free, with no credit card. If you'd like a hand setting up, ask, and we'll do it with you.

Questions people also ask

Is metal detection a CCP?

It is when your hazard analysis finds metal reasonably likely and the detector is the last control that can catch it before the food is sealed. The upstream controls, such as sieves, magnets and blade checks, still apply.

What size test pieces should a metal detector use?

The smallest ferrous, non-ferrous and stainless steel pieces the machine reliably detects in your product, set when it's installed. The example here uses 2.0, 2.5 and 3.0 mm.

How often should a metal detector be checked?

At the start and end of each run, at each product change, after stops and repairs, and at a set interval between. The interval decides how much product is held when a check fails.

Sources

  1. FDA Compliance Policy Guide Sec. 555.425: hard or sharp foreign objects 7 mm to 25 mm long in ready-to-eat food, or food needing only minimal preparation, considered adulterated; under 7 mm when a special-risk group is among the intended consumers · read November 20, 2026
  2. 21 CFR 117.165 (verification: instruments calibrated or checked for accuracy; monitoring and corrective action records reviewed within 7 working days) · read November 21, 2026

We use AI to help with the research for these articles. Every one is read, checked against its sources and edited by Koa before it's published. Spot a mistake? Tell us and we'll fix it and say so. How we write these.

Let’s get your stack in order.

Get TaroStack

Sign up now for your free 14 day trial. No credit card required.