Bottled water has its own federal rule, 21 CFR part 129, and a plant's HACCP plan is mostly that rule written out as control points. The source is approved and tested: at least once a year for chemical contaminants, and every week for total coliform when it isn't a public water system. The treatment is checked, and product water is sampled after it and before bottling. Bottles and caps are sanitized to stated minimums. Every package carries a production code. And finished water is tested for total coliform at least once a week for each type produced, and for chemical, physical and radiological quality at least once a year. Records stay at the plant for two years. Below are the rule's minimums, the control points, a week's log, and a worksheet.
The short version
- Source water: approved, tested yearly for chemicals, weekly for coliform if it's your own well or spring.
- Product water: sampled after treatment, before bottling.
- Sanitizing has minimum times and strengths. Measure and record them.
- A production code on every package, and records of where each code went.
- Finished water: total coliform weekly, full analysis yearly.
- TaroStack keeps each code as a lot, with its checks and its customers. More below.
What the rule asks for
| Area | The minimum | Where |
|---|---|---|
| Source water | An approved source. Chemical contaminants at least once a year, radiological every 4 years. Total coliform at least weekly unless the source is a public water system. A source with E. coli isn't used until it's fixed and retested | 129.35(a)(3) |
| Treatment | Effective for its purpose. Equipment inspections recorded. Product water sampled after processing and before bottling | 129.80(a) |
| Sanitizing | Steam or hot water at 170°F for 15 minutes, or 200°F for 5. A chemical sanitizer equal to 50 ppm available chlorine for 2 minutes. Ozone at 0.1 ppm for 5 minutes in an enclosed system | 129.80(d) |
| Containers and closures | Sampled and inspected. A swab or rinse count from at least four, at least every 3 months, with no coliform | 129.80(f) |
| Production code | On every unit package, identifying the batch and the day. Records of product, volume, date, code and distribution | 129.80(e) |
| Finished water | Total coliform at least once a week for each type. Chemical, physical and radiological at least once a year | 129.80(g) |
| Records | Kept at the plant for not less than 2 years | 129.80(h) |
The quality standard the finished water has to meet is in 21 CFR 165.110. Your state may add its own licence, testing and labeling rules on top.
The control points
A made-up plant filling 5-gallon returnable bottles and half-liter bottles from its own well. Limits beyond the rule's minimums are its own.
| CCP | Limit | Checked | If it's missed |
|---|---|---|---|
| 1 Treatment: filter, ultraviolet, ozone | UV lamp on with intensity above its alarm point; ozone residual at the filler in the plant's range, 0.2 to 0.4 ppm | Each hour | Filling stops; water since the last good check held |
| 2 Washing returnable bottles | Sanitizer rinse at 50 ppm available chlorine or more, 2 minutes | Test strip, each hour | Bottles since the last good check washed again |
| 3 Filling and capping | Every bottle capped, sealed and coded | Each bottle by eye; a pull test each hour | Uncapped or uncoded bottles rejected |
| 4 Finished water | No coliform in the weekly sample of each type | Each week | Follow-up test for E. coli; the codes covered held |
Returnable bottles are the plant's hardest job. A 5-gallon bottle comes back having held who knows what. Each one is looked at and smelled before it's washed, and anything doubtful is scrapped. The washer's temperature and sanitizer strength are the control, so they're measured, not assumed.
Treatment isn't a guarantee. Ozone and ultraviolet light work when the lamp is clean, the flow is within the unit's rating and the residual is where it should be. That's why the readings are hourly.
Positive release. The weekly coliform result comes back a day or more after the sample. A plant can ship before it arrives or hold that production until it does. Holding costs a day of warehouse space. Shipping first is the story at the end of this article.
A week's log
| Day | Check | Reading | Limit | OK? |
|---|---|---|---|---|
| Mon 10:00 | Ozone residual at the filler | 0.28 ppm | 0.2 to 0.4 ppm | Yes |
| Mon 10:05 | Washer sanitizer rinse | 60 ppm | 50 ppm or more | Yes |
| Wed 14:00 | Ozone residual at the filler | 0.12 ppm | 0.2 to 0.4 ppm | NO: act |
| Thu | Finished water, weekly sample, total coliform | Absent | Absent | Yes |
| Fri | Cap swabs, quarterly | No coliform | No coliform | Yes |
On Wednesday at 14:00 the ozone residual read 0.12 ppm: the generator's oxygen feed was failing. Filling stopped. The 180 bottles filled since the 13:00 reading were put on hold under their code, sampled, and released on Friday when the results came back clean.
This is general information, not legal advice. How to build a code is in how to create lot numbers, a cleaning procedure in sanitation SOP template, and record keeping in how long should HACCP records be kept.
Get the worksheet
Download the bottled water HACCP worksheet. Three sheets and a read-me: the hazard analysis from the source to the pallet, the plan with its four control points, and a monitoring log. It's an ordinary Excel file with no macros, and it works in Google Sheets, LibreOffice and Numbers.
Where this stops working
Take one case: Thursday's weekly sample comes back positive for coliform on Friday afternoon. Which codes does that sample stand for, how many bottles of each were made, and which delivery routes and stores have them now? The rule asks the plant to keep exactly that record: code, volume, date and distribution. On paper it's in three places.
How TaroStack does it
TaroStack keeps the code, the checks and the customers together.
Each production run is a batch with a lot code, and lot labels print with it. Your checks are fields on the batch record: ozone residual, sanitizer strength, time, initials.
A lot can wait on hold for its test result, kept out of what you can sell until it's released.
What ships is recorded by lot, so the record of where each code went is made as it leaves.
One report for a recall: which customers got the lot, how much, and what's still in the warehouse. Starting a recall holds the rest.
| The positive test | Paper | In TaroStack |
|---|---|---|
| Which codes the sample covers | The production diary | The batches of that day |
| Where they went | Route sheets and invoices | One report |
| What hasn't left | Walk the warehouse | Stock by lot, on hold |
| The hourly checks for that run | A clipboard | On the batch record |
TaroStack doesn't test water or replace a laboratory. Recipes, batches, lots and recalls are on every plan, from $9.99 a month (5 recipes) or $39 a month (50 recipes). The first 14 days are free, with no credit card. If you'd like a hand setting up, ask, and we'll do it with you.